Newscen Biopharm Co., Limited

Professional Manufacturer of Rapid Test Devices

Manufacturer from China
Active Member
5 Years
Home / Products / Syphilis Rapid Test Kit /

In Vitro Diagnostic 97.5% Accuracy Syphilis Rapid Test Kit

Contact Now
Newscen Biopharm Co., Limited
City:tianjin
Province/State:tianjin
Country/Region:china
Contact Person:MrRandy.Zhang
Contact Now

In Vitro Diagnostic 97.5% Accuracy Syphilis Rapid Test Kit

Ask Latest Price
Video Channel
Brand Name :Newscen
Model Number :TP (Treponema Pallidum) Syphilis
Certification :ISO9001, CE, TUV, FDA
Place of Origin :China
MOQ :10 Boxes or 400 Kits (40 Kits/Box)
Price :Negotiable as per Order Quantity
Payment Terms :T/T, Western Union, MoneyGram
Supply Ability :100,000 Kits Per Day
Delivery Time :8 days
Packaging Details :40 Kits/Box, 50 Boxes/Carton, 317g/Box, 18kgs/Carton, Box Size: 250x125x65mm, Carton Size: 650x510x330mm
Methodology :Colloidal Gold
Shelf Life :2 Years
OEM/ODM :Available
Usage :For In Vitro Diagnostic Use Only
Temperature Request :2-30°C
Manufacturer/Trader :Manufacturer
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Treponema Pallidum(TP) Rapid Diagnostic Kit (Colloidal Gold)

For the qualitative detection of Syphilis antibodies in serum/plasma and whole blood

Treponema Pallidum Syphilis Rapid Test Kit TP Home Use In Vitro Diagnostic Device

Main Features

☀ High Sensitivity: 100%

☀ Specificity: 100%

☀ Reliable: Accuracy higher than 97.5%, early detection of the presence of TP Antibody

☀ Convenient: Room Temperature Storage, Built-In Control

☀ Simple: No Instrument Required

☀ Fast: Results in 5-30 minutes, strong positive results may be observed promptly within 3 minutes

☀ Certified by Authoritative Certification System and Standards

☀ Winner of "the National Rapid Diagnostic Kit for Clinical Performance Assessment"

In Vitro Diagnostic 97.5% Accuracy Syphilis Rapid Test Kit

Intended Use


The Syphilis Rapid Diagnostic Test is a qualitative test for the detection of antibodies to Syphilis in human serum/plasma and whole blood. It is considered as an initial screening test for Syphilis antibodies. All positive specimens must be confirmed with Western Blot or other qualified EIA.

Principle


Syphilis Rapid Diagnostic Test is a chromatographic immunoassay (CIA) for the detection of antibodies to Syphilis in human serum or plasma. Syphilis specific antigens are precoated onto membrane as a capture reagent on the test region.

During the test, specimen is allowed to react with the colloidal gold particles, which have been labeled with Syphilis specific antigens. Antibodies to Syphilis, if present, a red colored band will develop on the membrane in proportion to the amount of Syphilis antibodies present in the specimen.

Absence of this red colored band in the test region suggests a negative result. To serve as a procedural control, a red colored band in the control region will always appear regardless the presence of antibodies to Syphilis. The RDT is simple, rapid, sensitive and specific.

In Vitro Diagnostic 97.5% Accuracy Syphilis Rapid Test Kit

Reagents and Materials Provided

☀ Blood diluent in a dropper bottle.

☀ One sealed pouched cassette with desiccant & a disposable pipe.

☀ One piece of operating instruction with 40 test pouches.

Sample Collection and Preparation

Whole Blood ( Finger stick Specimens)

☀ Clean the area to be lanced with an alcohol swab.

☀ Squeeze the end of the fingertip and pierce it with a sterile lancet.

☀ Wipe away the first drop of blood with sterile gauze or cotton.

☀ Allow the second drop to flow directly into a sample well.

Plasma

☀ Have a certified phlebotomist collect whole blood into a purple, blue or green top collection tube (containing EDTA, citrate or heparin, respectively) by veinpuncture.

☀ Separate the plasma by centrifugation.

☀ Carefully withdraw the plasma for testing or label and store it at 4°C for up to five days. Plasma may be frozen at -20°C for at least three months.

Serum

☀ Have a certified phlebotomist collect whole blood into a red top collection tube (containing no anticoagulants) by veinpuncture.

☀ Allow the blood to clot.

☀ Separate the serum by centrifugation.

☀ Carefully withdraw the serum for testing or label and store it at 4°C for up to five days. Serum may be frozen at -20°C for at least three months.

In Vitro Diagnostic 97.5% Accuracy Syphilis Rapid Test Kit

Assay Procedure

Serum or Plasma Sample

Add 2 drops of serum or plasma into sample well. Observe the result in 120 minutes.

Whole Blood Sample

Add 1 drop of whole blood into sample well, after all blood completely absorbed. Add 2 drop of whole blood diluent. Observe the result in 20 minutes.

In Vitro Diagnostic 97.5% Accuracy Syphilis Rapid Test Kit

Interpretation of Results

In Vitro Diagnostic 97.5% Accuracy Syphilis Rapid Test Kit

Negative: No apparent band in the test region (T), Only one red band appears in the control region (C). This indicates that no TP antibodies have been detected.


Positive: In addition to one red band in the control region (C), a red band will appear in the test region (T). This indicates that the specimen contains TP antibodies.


Invalid: If no band appears in the control region(C), regardless of the presence or absence of band in the test region (T). It indicates a possible error in performing the test. The test should be repeated using a new device.

Warning and Precautions

☀ FOR IN VITRO DIAGNOSTIC USES ONLY.

☀ All patient samples should be treated as if capable of transmitting diseases.

☀ Do not interchange reagents from different lots or use test kit beyond expiration date.

☀ Icteric, lipemic, hemolysed, heat treated and contaminated sera may cause erroneous results.

Storage


Store the test kits at temperature 4-30°C,in the sealed pouch for the duration of the shelf life (24 months).